( full specifications are in the manual for the device )
1. Volumetric and mass cost calculators VR-2 and PK-V calculators are designed to build measuring
complexes, common marking FLOWTECH-TM-1 and FLOUTEC-TM-2, and calculation of the volume flow and volume of gas passed through
measuring pipeline for a given period of time with volume flow and gas volume reduced to standard (normal)
conditions according to GOST 2939-63.
- Computer VR-2 provides measurement of gas volumes through three measuring pipelines in different versions
used measuring transducers (sensors).
- PC-V calculators provide measurement of gas volumes through one measuring pipeline.
Calculator VR-2 and Calculators PC-V are a means of measurement.
2. Calculator BP-2 and Calculators PK-V comply with the Technical Regulations for Measuring Instruments approved
CMU Decree No. 163 dated February 24, 2016.
3. The body of the VR-2 Calculator and the PK-V Calculators are metal, explosion-proof and comply with the Technical Regulations
approved by the Decree of the Cabinet of Ministers of December 28, 2016 No. 1055 and have an explosion protection marking
II 2G Ex ib IIB T3 Gb
and can be installed in hazardous areas in accordance with the requirements of regulatory documents governing the use
electrical equipment in hazardous areas with their mandatory sealing by the manufacturer.
4. The VR-2 Computer and PC-V Computers are powered from an external DC power supply. In the absence of the main power supply,
the data in the Calculator's memory is stored using a spare lithium battery, the capacity of which is sufficient in order not
to change the battery during their operation.
The battery provides a mode of storing calculated information for up to 1,000 hours without connecting the main
nutrition.
1. Complexes FLOUTEC-TM-1 and FLOUTEC-TM-2 can be used for metering
(including commercial metering) of gas at industrial facilities, gas facilities, oil and gas producing, oil refining and petrochemical
industries, at public utilities, as well as as part of automated commercial accounting systems The objects are, in particular, units
for measuring current parameters gas measuring points, gas distribution stations (GDS), compressor stations of main gas pipelines,
gas distribution points, etc.
2. The limits of the permissible relative error of complexes when measuring volumetric (mass) costs and volume (mass) of the
medium (excluding methodological errors when using standard constriction device or averaging pressure tube) are (depending on the error
measuring transducers for temperature, pressure, differential pressure and density and pressure ranges and differential pressure of
the medium on the indicated devices) - not worse than ±0.5%.
3. Archives are accumulated and stored separately for each measured flow in the non-volatile memory of the complexes in the following volume:
- daily archive, not less than for the last 6 months;
- hourly archive, not less than for the last 2 months;
- archive of operational (periodic) data, no less than 3,600 records;
- operator intervention archive, at least 1000 records;
- archive of events, at least 1000 records;
- archive of emergency and freelance situations, no less than 1200 records;
- security archive, no less than 1200 records.
4. The design of the Calculators provides the possibility of setting, according to the order, the limits of measurements in the ranges:
- from 100 kPa to 10 MPa - for absolute pressure;
- from 6.0 kPa to 25 MPa  - for excessive pressure;
- from 1.0 to 256 kPa - for differential pressure.
5. Operation of the VR-2 Calculator and PC-V Calculator is allowed at a temperature ambient air from minus 40 to plus 70 °C.
6. Electrical power is provided by DC voltage. . . . . . . . - 8 to 15 V
7. Power consumed by devices:
- Calculator VR-2 - no more than 0.65 W
- PC-V calculators - no more than 1.25 W
8. Overall dimensions of devices do not exceed:
Calculator VR-2 - 210 x 360 x 100 mm
PC-V calculators:
- PC-V version 1 - 120 x 237 x 228 mm
- PC-V version 2 - 137 x 138 x 161 mm
9. The mass of devices is not more than:
- computer VR-2 . . . . . . . . . . . . - 3.2 kg
- PC-V calculators . . . . . . . . . . . - 4.5 kg
10. Life time . . . . . - at least 12 years old.
Volume and mass calculator BR-2 expenses.
Calculator PC-V.
Measuring complexes FLOUTEK-TM. Operation manual.
To update the software of FLOUTEC-TM measuring Complexes go to the following link:
HostWin - Maintenance program for FLOUTEC-TM Complexes of all modifications (survey, accumulation
and viewing information, issuing commercial reports on the consumption of the measured medium)
If the measuring complex FLOUTEC-TM contains the "Initiative Interface Converter", it is necessary to additionally
apply the program InitCntrPack.rar.
Run the "Conf.exe" application from the specified package and configure the proactive interface converter in it.
manual.pdf - Instructions for working with HostWin with an initiative interface converter
as part of the FLOUTEC-TM measuring complex
CONCOR - The program for the configuration of calculators (correctors) of all modifications of
measuring complexes FLOUTEC-TM
USB Port Driver for communication with the computer VR-2
Type Examination Certificate. (Calculator VR-2)
Type Examination Certificate. (PC-V converters)
Type-examination Certificate (FLOUTEC-TM measuring systems)
Notice of type conformity based on quality assurance of the production process
Quality Management System Approval Certificate (module D)
Certificates, Permits. . . (full list)