( full specifications are in the manual for the device )
1. The isolating RS232 hub is intended for conversion
physical signal levels of the RS232 interface into physical signal levels of the RS232 interface with galvanic isolation
specified signal interfaces.
2. The isolating RS232 hub is used to organize the exchange of digital information between industrial controllers,
PCs, modems with an RS232 interface.
The concentrator implements the "logical 1" function of signals of the same name coming from connected devices and
transmitted accordingly to all devices connected to hub connectors.
3. The isolating RS232 hub is not a measuring device.
1. Power parameters of the RS232 Concentrator isolating from
external direct current source:
- nominal supply voltage - from 10 V to 30 V;
- own consumption current. . . . . - no more than 170 mA.
- power consumption at nominal voltage. . . . . - no more than 2.0 W.
2. The overall dimensions of the isolating RS232 hub do not exceed - 157 x 95 x 58 mm.
3. The mass of the isolating RS232 concentrator does not exceed - 0.25 kg.
4. The RS232 isolating hub is not a means of measurement.
5. The isolating RS232 concentrator is intended for operation outside explosive zones.
6. Operation of the RS232 isolating concentrator is allowed at an ambient air temperature of minus 30 to plus 60 °C.
7. The service life of the insulating RS232 hub is 12 years.
1. The isolating RS232 concentrator is made in a plastic case with brackets for mounting on a DIN rail.
At the same time, the insulating RS232 hub must be protected from direct exposure
atmospheric precipitation.
2. The isolating RS232 hub is designed for outdoor use
explosive zones indoors at an ambient air temperature of minus 40 to plus 60 °C.
3. Climatic execution of C-4 according to GOST 12997-84. Degree of protection against environmental action IP30 according to GOST 14254-80.
4. The company provides warranty service for the isolating RS232 Concentrator for 24 months and service
throughout the service life.